LoughLght Getting started

Help · Getting started · 45 minutes

Getting started with LoughLight

What each part of LoughLight is for, and a tour of the example data: releases and gates, the factory, the field, and following a fault from a few failed units to every unit like them.

LoughLight LtdNovember 2026Getting started

This guide explains what each part of LoughLight does, then walks you through the example data, a made-up company that makes environmental sensors. Each stop takes a few minutes. You don't need to be a tester to follow it: if you've ever asked "is this ready to ship?" or "which other units have this problem?", LoughLight is built for you.

What LoughLight is

LoughLight follows a product from design, through the factory, to the field. It's three tools in one, sharing the same products, units and audit trail:

SectionWhat it's for
ChartReleases and tests. Write test cases, plan a release in phases, run tests against builds, and pass gates with named approvers.
SlipwayThe factory. End-of-line test results for every unit, yields, containment of suspect units, and investigating faults.
BeaconThe field. Units shipped to customers and what they report, customer betas, alerts and returns. For software, versions and release rings.

Everything that matters goes to the Logbook, a tamper-evident record of who did what and when. That's what makes LoughLight useful to companies that get audited, such as those working to ISO 9001 or ISO 13485.

Words to know

How the pieces fit

Product → Suites → Cases  (the library of tests)

Product → Releases → Phases → Runs → Results  (testing one version)

Product → Work orders → Units → Customers  (building and shipping it)

WordMeaning
ProductSomething you make: a device, an app, a cloud service. A system is a product made of other products.
CaseOne test: its steps and expected results. It lives in a suite in the product's library and is reused by every release, never copied.
ReleaseA version you're testing, like "Humidity sensor 1.2". Its scope is the cases it tests; its builds are the versions handed to testing.
Phase and gateA release moves through phases (Component, Integration, System test, Customer beta). Each starts with a plan review and ends with a gate, where approvers sign a decision.
RunA set of cases tested against one build, each with a result: pass, fail or blocked.
Work orderA batch of units built together in the factory, each tested at the end of the line.
ContainmentSuspect units held while a problem is worked out, each with a decision: retest, rework, release or scrap.
BetaA release's units (or a software version's users) in real customers' hands, judged against production before launch.
LogbookThe permanent, tamper-evident record of every change, result and decision.

Finding your way

The sidebar has two halves. The top half is views across everything; below it, one section per audience. Only the open section shows its pages. The Product picker narrows every page to one product (or a family), and you can pin up to five releases or dashboards.

PageWhat it does
HomeWhat needs you: your actions, reviews waiting for you, cases to approve, mentions in comments, and the releases you follow.
PortfolioEvery product's design, production and field side by side, with what needs attention first. Open a product for its own page.
DashboardsYour own and shared dashboards of widgets: progress, gates, charts, factory yields, beta figures. Anyone can make one.
ReportsSaved reports run now as a PDF or spreadsheet, or emailed on a schedule, such as a release readiness pack.
DecisionsDecisions with who made them, their evidence and the actions that follow. Never edited, only replaced.
Chart › ReleasesEvery release, as a table or a phase board. Open one for its Overview, Phases, Requirements, Test runs, Test cases and, when it has them, Builds and Beta.
Chart › Case libraryEach product's suites and cases, shared steps, case review, and importing cases from a spreadsheet or TestRail.
Slipway › OverviewThe line today against its week: tests, pass rate, each station, open containments and collectors needing a look.
Slipway › Work ordersEach build's yields, what failed, every measurement against its limits, every unit, and batch records for audits.
Slipway › ContainmentSuspect units on hold, and investigations: from a few failures to the probable link and every unit like them.
Slipway › Stations and specsThe line's test stations, the limits units are tested to, collectors and data sources, and hourly data seals.
Beacon › Overview, FleetUnits in the field and how they're doing; for software, versions and rings.
Beacon › Active betasEach running beta: its units or users, exit criteria with how confident each figure is, and the beta against production.
Beacon › Customers, Alerts, ReturnsEach customer's fleet, alerts raised by monitors, and units sent back with their history frozen.
Dry dockA sandbox for projects not ready for the main view, invisible to anyone outside the bay.
LogbookThe audit trail. Its overview checks the chain, proving nothing has been altered; factory and field entries are kept apart.
API, Settings, HelpThe JSON API for scripts and CI; users, tokens, notifications, integrations and the licence; and this guide.

Press ⌘K (or Ctrl K) to search for anything: a release, a case, a unit by serial, MAC or IMEI, or a page. Press ? for keyboard shortcuts. If your company has connected its own AI, Ask answers questions about your data and suggests changes for you to approve.

A tour of the example data

The example company makes three environmental sensors, each release at a different point: the Water level sensor 2.0 is in a customer beta, the Temperature sensor 3.0 is being planned, and the Humidity sensor 1.2 is in System test. The Water level portal is the web app the sensors report into. Everything is made up.

On your own LoughLight

An admin can add the same examples with loughlight example-data sensors. Use a trial or test install: example data isn't for a live one.

1. Home and the Portfolio

  1. Open Home. It lists what needs you, so it's where most days start.
  2. Open Portfolio. Each sensor shows its design (the release and next gate), production (yield and containment) and field (units, alerts, returns) side by side.
  3. Pick All Environment sensors in the Product picker: every page now shows just that family. Pick All products to go back.

2. Is the Water level sensor 2.0 ready?

  1. In Chart › Releases, open Water level sensor 2.0.
  2. Overview shows how many requirements are tested and what's failing or blocked. Phases shows Component, Integration, System test and an internal Alpha all passed, each gate signed by its approvers.
  3. The Customer beta is running: 120 sensors at two water companies. Open the Beta tab for its exit criteria, each with how confident the figure is so far.

Ask yourself: could you tell a colleague whether this release is ready, and why, in under a minute?

3. Plan a release

  1. Open Temperature sensor 3.0 › Phases. Its phases are drawn up and its first plan review is open, signed by one approver of two.
  2. A release's scope freezes when its first plan review passes. After that, new cases are proposals and rule changes need a reason, all in the Logbook.

4. Write and review a test case

  1. Open Chart › Case library and pick the Humidity sensor.
  2. Choose a suite and add a case: a title, two or three steps and what you expect. Try Test data to run the same case with several sets of values, or Add shared steps to reuse a block of steps.
  3. Send it for review. Someone else approves it; the person who sent it can't.

5. Run some tests

  1. Open Humidity sensor 1.2 › Test runs. System test cycle 1 closed with failures; cycle 2 is half done.
  2. Open cycle 2 and record a few results: pass, fail or block, with a note on a failure. Attach a log file or a screenshot to a result.
  3. To start a new run, choose New test run and a starting point, such as Failed and blocked or Priority 1.
  4. Your CI can send results too: JUnit or Robot Framework files, imported into a run (see API).

6. A system and its launch gate

  1. Open Water level system 2.0. It's made of two releases, the sensor 2.0 and the portal 3.0, tested separately and shipped together.
  2. Its Launch decision gate reads both betas, so one decision covers the whole system.

7. The field: betas, software and returns

  1. Open Beacon › Active betas and the water level sensor's beta: the units, the customers, and the beta against the production fleet of version 1.6.
  2. Pick Water level portal in the Product picker and open Beacon › Fleet (Versions, for software). Version 3.0.0 in the beta ring brought a new error, AlarmQueueStall; 3.0.1 fixed it.
  3. Look at Alerts and Returns: a return freezes the unit's recent reports, so you can see what it did before it failed.

8. The factory

  1. Open Slipway › Overview: the line's tests and pass rate today against its week.
  2. Open Work orders and WO-8090, a production build of the water level sensor. Its first-pass yield is lower than the earlier builds: units are failing level_offset_mm, the level reading's accuracy.
  3. Choose the measurement to see every value over time against its limits. Something changed partway through the build. The next section finds out what.

Slipway: investigating a fault

When units fail, the hard questions are why and which other units have the same problem. An investigation answers both. It compares the failed units with good units from the same builds and ranks what's different about them, then finds every unit with that difference: still in the factory, or already shipped.

It points to a probable link, not a cause. An engineer decides what caused the fault; LoughLight shows the evidence.

Step 1: start from the failures

  1. On WO-8090, in the Containment panel, choose Investigate failures. The units that failed are filled in for you; you could also paste serials from a returns list.
  2. Choose Start. The investigation opens on its own page, with its steps down the page.

Step 2: set the bounds

Bounds say which units are looked at: built from a date, some work orders, some lines. The defaults (the product's units built from a month before the first failure) are a good start.

Step 3: find the probable links

  1. Choose Find probable links. The failures are compared with up to 300 good units, spread across work orders and build weeks.
  2. The findings are ranked strongest first. At the top: afe_fw 3.3.0, the firmware of the sensor's analogue front end. Every failure has it, against about a quarter of good units.
ColumnWhat it tells you
Failures / Good unitsHow many failures had the value, against good units. For a reading, both groups' middle values, with a chart of every unit.
Chance by luckHow likely a difference this big is by chance alone, allowing for how many things were compared.
ConfidenceEarly, building or solid: how much weight the finding can bear, given how many failures there are.

Read the notes under each finding. Some values always occur together in the data, such as a work order and the firmware it was loaded with, and LoughLight says it can't tell them apart. A reading the units failed on, and retests after failing, are marked as no surprise and ranked last.

What a finding can draw on: attributes (component firmware, lot codes, fixture, operator, station, build day), readings at every station (including ones that passed but sat near a limit) and test history (retests, time between tests). Component firmware and lot codes come with each result, from the line's test software or LoughLight's collector.

Step 4: build the rule

  1. Tick afe_fw 3.3.0. It becomes the rule, and a live count shows how many units match and how many of the failures are among them.
  2. For a reading, ticking it suggests a cut-off, the value that best separates failures from good units. Change it and watch the count.
  3. Under Where the units are, choose Both to include units already shipped.

Step 5: find the other units

  1. Choose Find other units. Every sensor with the new firmware is listed, grouped by where it is: about 120 still in the factory and some already shipped to Lakeside Water.
  2. LoughLight also notices the Humidity sensor uses the same front end: 30 of its units have 3.3.0. The investigation stays on the water level sensor; for the humidity sensor, choose Investigate it (a linked investigation) or No action with a reason.
  3. Download the whole list as CSV or Excel, for example to send to a customer.

Step 6: contain them

  1. Leave out any unit you know is fine (a reason is needed), then choose Contain.
  2. The containment marks each unit as an original failure or a suspect. Units in the factory go on hold; shipped ones are marked for follow-up in Beacon.
  3. Everything the decision was based on is frozen: the failures, the good units, every finding, the rule and the units. Its fingerprint (SHA-256) goes in the Logbook, and Evidence downloads exactly what was fingerprinted, for an auditor.

If the links are too weak to act on, choose Close without action with a reason: the findings are kept as evidence either way.

Everything else

Getting help

This guide is always under Help in the sidebar and in the search (⌘K). The install guide and the guides for the collector, automated results and Beacon for software come with every download, in the docs folder. If your company has connected its own AI, Ask can explain what's on the page you're looking at.

Thank you for using LoughLight. It's made by LoughLight Ltd, an independent software company registered in Northern Ireland. Every piece of feedback is read, and the best ideas end up in the product.